loading
LOADING IMAGES

RYT-L200W12

  • Model Number:  RYT-L120W12
  • Rated Power:   200W
  • Application:  LED, access control
  • Fan Type:  Natural cooling
  • Power Type:  Switching power supply
  • Input Voltage:  100-240VAC
  • Line type:  Single terminal group
  • Dimention:  199x110x50mm
  • Packaging Details:  30pcs/ctn
  • Carton Dimention:  455x287x380mm

10 Other Products in the same category

Product Features

*Small size, light weight
*High reliability, low price
*High conversion efficiency
*It has a basic protection circuit,good ability to adapt to the environment
*100% full load burn and a full range of functions
* Output over voltage protection
* Short circuit protection on all outputs
*Switching frequency: 25KHz
*LED power indicator
*AC input range by switch
*100% full load burn-in test
* Natural air

Product Details

Model

L200W12-5

L200W12-7.5

L200W12-12

L200W12-15

L200W12-24

L200W12-27

L200W12-48

output

DC voltage

5V

7.5V

12V

15V

24V

27V

48V

 

Rated current

40A

26.6A

16.6A

13A

8.3A

7.4A

4.1A

 

Current range

0-40A

0-26.6A

0-16.6A

0-13A

0-8.3A

0-7.4A

0-4.1A

 

Rated power

200W

200W

200W

200W

200W

148W

200W

 

Ripple and noise

100mv

120mv

120mv

120mv

200mv

200mv

240mv

 

Voltage adjustment range

4.5-5.5V

6-8.3V

10.6-13.2V

132.-16.5V

21-28V

24.5-29.5V

43.2-52.8V

 

Voltage Accuracy

+/-2%

+/-1%

+/-1%

+/-1%

+/-1%

+/-1%

+/-1%

 

Line Regulation

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

 

Load Regulation

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

 

Start / ramp / soak time

100ms / 50ms / 20ms (Loaded)

Input

Voltage range

176-264VAC or Switc 90-132VAC

 

Frequency Range

47-63Hz

 

effectiveness

78%

82%

82%

84%

86%

87%

87%

 

AC current

3A/115VAC 1.5A/230V

 

Inrush current

Cold start 32A

 

Leakage Current

<3.5mA/240VAC

Protection

Overload

Rated power 125%-165% /  protection mode:close output,recovery  after restart

 

Overvoltage

5.6-6.8V

8.6-10V

13.8-16.2V

17.3-20.3V

29-32V

31.05-36.45V

55.2-63.8V

 

Short circuit

Short-circuit protection, automatic recovery

Environment

Operating temperature

-10℃ - 60℃(Referring to the load derating curve)

 

Working humidity

20-90% RH Non-condensing

 

Storage temperature and humidity

-20℃ - +85℃, 10-95%RH

 

Temperature Coefficient

+/-0.03%℃(0-50℃)

 

Vibration resistance

10-500Hz.2G 10min/cycle,X, Y, Z axes of 60 minutes

Safety and

Electromagnetic Compatibility

Safety rules

UL1012 reference design

 

Pressure

I/P-O/P:1.5KVAC,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC

 

Insulation Resistance

100M Ohms/500VDC 70%RH

 

certified product

CE

Othes

MTBF

>300KH

 

Dimension

199*110*50mm(L*W*H)

 

Weight

0.88Kg

 

Product Related Information

Downloads