RYT-S145

  • Model Number:  RYT-S145
  • Rated Power:   145W
  • Application:  LED, access control
  • Fan Type:  Natural cooling
  • Power Type:  Switching power supply
  • Input Voltage:  100-240VAC
  • Line type:  Single terminal group
  • Dimention:  199x98x38mm
  • Packaging Details:  30pcs/ctn
  • Carton Dimention:  455x287x380mm

10 Other Products in the same category

Product Features

*Small size, light weight
*High reliability, low price
*High conversion efficiency
*It has a basic protection circuit,good ability to adapt to the environment
*100% full load burn and a full range of functions
* Output over voltage protection
* Short circuit protection on all outputs
*Switching frequency: 25KHz
*LED power indicator
*AC input range by switch
*100% full load burn-in test
* Natural air

Product Details

Model

S145-5

S145-7.5

S145-12

S145-15

S145-24

S145-27

S145-48

output

DC voltage

5V

7.5V

12V

15V

24V

27V

48V

Rated current

29A

19A

12A

10A

6A

5.4A

3A

Current range

029A

0-19.2A

0-12A

0-9.6A

0-6A

0-5.4A

0-3A

Rated power

145W

143W

144W

150W

145W

146W

144W

Ripple and noise

100mv

120mv

120mv

120mv

150mv

200mv

240mv

Voltage adjustment range

4.5-5.5V

6-8.3V

10.6-13.2V

132.-16.5V

21-28V

24.5-29.5V

43.2-52.8V

Voltage Accuracy

+/-2%

+/-1%

+/-1%

+/-1%

+/-1%

+/-1%

+/-1%

Line Regulation

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

Load Regulation

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

+/-0.5%

Start / ramp / soak time

100ms / 50ms / 20ms (Loaded)

Input

Voltage range

176-264VACor Switch90-132VAC

Frequency Range

47-63Hz

effectiveness

78%

82%

82%

84%

84%

85%

85%

AC current

3A/115VAC 1.5A/230V

Inrush current

Cold start 32A

Leakage Current

<3.5mA/240VAC

Protection

Overload

Rated power125%-165% / protection mode:close output,recovery  after restart

Overvoltage

5.6-6.8V

8.6-10V

13.8-16.2V

17.3-20.3V

29-32V

31.05-36.45V

55.2-63.8V

Short circuit

Short-circuit protection, automatic recovery

Environment

Operating temperature

-10℃ - 60℃(Referring to the load derating curve)

Working humidity

20-90% RH Non-condensing

Storage temperature and humidity

-20℃ - +85℃, 10-95%RH

Temperature Coefficient

+/-0.03%℃(0-50℃)

Vibration resistance

10-500Hz.2G 10min/cycle,X, Y, Z axes of 60 minutes

Safety and

Electromagnetic Compatibility

Safety rules

UL1012 reference design

Pressure

I/P-O/P:1.5KVAC,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC

Insulation Resistance

100M Ohms/500VDC 70%RH

certified product

CE

Othes

MTBF

>300KH

Dimension

199*99*38mm(L*W*H)

Weight

0.78Kg