RYT-S145
-
Model Number: RYT-S145 -
Rated Power: 145W -
Application: LED, access control -
Fan Type: Natural cooling -
Power Type: Switching power supply -
Input Voltage: 100-240VAC -
Line type: Single terminal group -
Dimention: 199x98x38mm -
Packaging Details: 30pcs/ctn -
Carton Dimention: 455x287x380mm
10 Other Products in the same category
Product Features
*Small size, light weight
*High reliability, low price
*High conversion efficiency
*It has a basic protection circuit,good ability to adapt to the environment
*100% full load burn and a full range of functions
* Output over voltage protection
* Short circuit protection on all outputs
*Switching frequency: 25KHz
*LED power indicator
*AC input range by switch
*100% full load burn-in test
* Natural air
Product Details
Model |
S145-5 |
S145-7.5 |
S145-12 |
S145-15 |
S145-24 |
S145-27 |
S145-48 | |
output |
DC voltage |
5V |
7.5V |
12V |
15V |
24V |
27V |
48V |
Rated current |
29A |
19A |
12A |
10A |
6A |
5.4A |
3A | |
Current range |
029A |
0-19.2A |
0-12A |
0-9.6A |
0-6A |
0-5.4A |
0-3A | |
Rated power |
145W |
143W |
144W |
150W |
145W |
146W |
144W | |
Ripple and noise |
100mv |
120mv |
120mv |
120mv |
150mv |
200mv |
240mv | |
Voltage adjustment range |
4.5-5.5V |
6-8.3V |
10.6-13.2V |
132.-16.5V |
21-28V |
24.5-29.5V |
43.2-52.8V | |
Voltage Accuracy |
+/-2% |
+/-1% |
+/-1% |
+/-1% |
+/-1% |
+/-1% |
+/-1% | |
Line Regulation |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% | |
Load Regulation |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% |
+/-0.5% | |
Start / ramp / soak time |
100ms / 50ms / 20ms (Loaded) | |||||||
Input |
Voltage range |
176-264VACor Switch90-132VAC | ||||||
Frequency Range |
47-63Hz | |||||||
effectiveness |
78% |
82% |
82% |
84% |
84% |
85% |
85% | |
AC current |
3A/115VAC 1.5A/230V | |||||||
Inrush current |
Cold start 32A | |||||||
Leakage Current |
<3.5mA/240VAC | |||||||
Protection |
Overload |
Rated power125%-165% / protection mode:close output,recovery after restart | ||||||
Overvoltage |
5.6-6.8V |
8.6-10V |
13.8-16.2V |
17.3-20.3V |
29-32V |
31.05-36.45V |
55.2-63.8V | |
Short circuit |
Short-circuit protection, automatic recovery | |||||||
Environment |
Operating temperature |
-10℃ - 60℃(Referring to the load derating curve) | ||||||
Working humidity |
20-90% RH Non-condensing | |||||||
Storage temperature and humidity |
-20℃ - +85℃, 10-95%RH | |||||||
Temperature Coefficient |
+/-0.03%℃(0-50℃) | |||||||
Vibration resistance |
10-500Hz.2G 10min/cycle,X, Y, Z axes of 60 minutes | |||||||
Safety and Electromagnetic Compatibility |
Safety rules |
UL1012 reference design | ||||||
Pressure |
I/P-O/P:1.5KVAC,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC | |||||||
Insulation Resistance |
100M Ohms/500VDC 70%RH | |||||||
certified product |
CE | |||||||
Othes |
MTBF |
>300KH | ||||||
Dimension |
199*99*38mm(L*W*H) | |||||||
Weight |
0.78Kg |